Environmental Policy

“MINIMAL POLLUTION TO THE ENVIRONMENT AND CONTINUAL IMPROVEMENT OF ENVIRONMENTAL PERFORMANCE ARE OUR RESPONSIBILITIES.” 

THE GOALS

  1. To provide an accident-free workplace for all employees, contractors, third parties.
  2. To limit the negative impact of our operations on the environment.
  3. To minimize environmental pollution and continue to improve in environmental performance.

THE PROCEDURES

  • Implement an environmental management program which shall best comply with legislations, regulations and other requirements in the Environmental Quality Act 1974.
  • Avoid spills, leaks or accidental discharges of polluting materials to air, water and land.
  • Increase employees’ awareness on environmental issues by providing seminars and trainings.
 

MAGNALIUM SDN. BHD. expects all employees, contractors and third parties to understand the policy and always adhere to the abovementioned goals and procedures. This policy is subject to change as deemed necessary by the management.

 

POLISI ALAM SEKITAR

“MENGURANGKAN PENCEMARAN ALAM SEKITAR ADALAH TANGGUNGJAWAB SEMUA”

MATLAMAT

  1. Mengelakkan kemalangan di kalangan para pekerja, kontraktor, pihak ketiga.
  2. Menghadkan kesan operasi kami terhadap alam sekitar.
  3. Mengurangkan pencemaran alam sekitar dan meningkat prestasi alam sekitar berterusan.

PROSEDUR

  1. Melaksanakan program pengurusan alam sekitar yang sesuai mengikut undang-undang dalam Akta Kualiti Alam Sekeliling 1974.
  2. Mengelakkan tumpahan, kebocoran atau pelepasan bahan pencemar ke udara, air dan tanah.
  3. Meningkatkan kesedaran pekerja mengenai isu-isu alam sekitar dengan seminar dan latihan.

MAGNALIUM SDN. BHD. berharap semua kakitangan dan kotraktor akan sentiasa mematuhi polisi ini. Pihak pengurusan akan mengkaji polisi ini dari semasa ke semasa.

Facilities

Air Pollution Control System
Scheduled Waste Management
Scheduled Waste Management

Ambient Air Monitoring Report

The high-volume ambient air monitoring to be conducted to determine the 24hours ambient air concentration level for compliance with the Malaysia Ambien Air Quality Standard for Particulate Matter PM10 and Particulate Matter PM2.5.

Parameter

Total Suspended Particulate (TSP) 24 hours

Location

Nearby Magnalium Sdn Bhd Guard House

Carried out by

CNL Consultants (Northern) Sdn Bhd

Malaysian Ambient Air Quality Standard

150 µg/m3 (24hours averaging time)

Malaysian Ambient Air Quality Standard 2020 (PM10):

100 µg/m3 (24hours averaging time)

Malaysian Ambient Air Quality Standard 2020 (PM2.5):

35 µg/m3 (24hours averaging time)

Date
April’2017
August’2017
December’2017
May’2018
August’2018
December’2018
Result 49.50 µg/m3 49.50 µg/m3 32.29 µg/m3 24.96 µg/m3 33.20 µg/m3 76.72 µg/m3

Date
July’2019
December’2019
May’2020
October’2020
April’2021
October’2021
March’2022
November’2022
April’2023
December’2023
Result PM10 74.35 µg/m3 96.03 µg/m3 24.23 µg/m3 84.81 µg/m3 91.70 µg/m3 76.14 µg/m3 54.23 µg/m3 87.61 µg/m3 88.20 µg/m3 92.91 µg/m3
Result PM2.5 33.04 µg/m3 25.05 µg/m3 16.16 µg/m3 32.31 µg/m3 25.01 µg/m3 29.61 µg/m3 29.19 µg/m3 33.38 µg/m3 33.60 µg/m3 12.67 µg/m3

Isokinetic Stack Air Emission Monitoring Report

The isokinetic air emission monitoring to be conducted to evaluate the air emission form the identified dust collector chimney start for establishing the compliance of such to the governing guidelines for environmental discharge under the Environmental Quality (Clean Air) Regulations 2014.

Location

Dust Collector Chimney Exhaust Outlet

Carried out by

CNL Consultants (Northern) Sdn Bhd

Environmental Quality (Clean Air) Regulation 2014, Regulation 13 Standard

50 mg/3

Date
Parameter
April’2017
August’2017
December’2017
May’2018
August’2018
December’2018
Result Total Particulate Weight Caught 0.005gm 0.003gm 0.0028gm 0.0017gm 0.0013gm 0.0011gm
Total Particulate Concentration 31.25mg/3 5.97 mg/3 4.99mg/3 7.025mg/3 9.31mg/3 2.67mg/3
Emission Rate 1.80kg/hr 0.21kg/hr 0.31kg/hr 0.61kg/hr 0.41kg/hr 0.28kg/hr
Velocity Flue Gas 10.9m/s 0.21kg/hr 11.9m/s 16.3m/s 7.80m/s 18.3m/s

Parameter
July’2019
December’2019
May’2020
October’2020
April’2021
October’2021
March’2022
November’2022
April’2023
Result Total Particulate Weight Caught 0.0028gm 0.008gm 0.0004gm 0.0004gm 0.0006gm 0.0018gm 0.0007gm 0.0009gm 0.0010gm
Total Particulate Concentration 8.96mg/m3 2.23mg/m3 3.37mg/m3 4.12mg/m3 1.90mg/m3 7.53mg/m3 2.60mg/m3 0.80mg/m3 1.22mg/m3
Emission Rate 0.89kg/hr 0.015kg/hr 0.18kg/hr 0.236kg/hr 0.212kg/hr 0.491kg/hr 0.116kg/hr 0.054kg/hr 0.116kg/hr
Velocity Flue Gas 18.7m/s 1.24m/s 10.2m/s 10.8m/s 21.1m/s 12.3m/s 8.4m/s 12.7m/s 17.8m/s

Environmental Competency

Name

Ting Chien Cher

Position

Certified Environmental Professional in Bag Filter Operation (CePBFO)

Certified since

June 29, 2021

Link to NRCEP

Name

Loo Win Sing

Position

Certified Environmental Professional in Scheduled Waste Management (CePSWaM)

Certified since

August 08, 2018